Disclosure: Manufacturer links on this site are plain links, not affiliate links yet. If that changes we may earn a commission at no cost to you, and this notice will say so. We have not tested any product; all performance figures come from ENERGY STAR certification data, and cost and room-size figures are estimates. Learn more.

Blueair Pure 411: CADR, room size and running cost

Smoke CADR 98 cfm · Room size 152 sq ft (ENERGY STAR) · 64 kWh/yr ≈ $11.72/yr electricity (estimate)

Certified specs

Smoke CADR98 cfm
Dust CADR107 cfm
Pollen CADR127 cfm
PM2.5 CADR103 cfm
ENERGY STAR effective room size152 sq ft (1.55 × smoke CADR, per 10 CFR 429.68)
Annual energy use64 kWh/yr
Integrated energy factor9.1 cfm/W
Smoke CADR per watt12.25 cfm/W
Ozone emissions (reported)1 ppb
TechnologyFan and Filter
Filter types listedHEPA-Type
Automatic modeAir Quality Sensor
Connected (app/Wi-Fi)No
ENERGY STAR Most EfficientYes
MarketsUnited States, Canada
Date certified2025-05-20
ENERGY STAR partnerBlueair Inc.
SourceENERGY STAR record 4046729 · Product Finder page

How many air changes per hour would it give?

Estimate: air changes per hour (ACH) = smoke CADR × 60 ÷ room volume, at the top fan speed used for the CADR test. Real-world ACH is usually lower (lower fan speeds, furniture, filter loading).

RoomACH, 8 ft ceilingACH, 9 ft ceilingAHAM sizing
100 sq ft7.36.5Meets AHAM 2/3 rule
150 sq ft4.94.4Below AHAM 2/3 rule
200 sq ft3.73.3Below AHAM 2/3 rule
300 sq ft2.52.2Below AHAM 2/3 rule
400 sq ft1.81.6Below AHAM 2/3 rule
500 sq ft1.51.3Below AHAM 2/3 rule
700 sq ft1.10.9Below AHAM 2/3 rule

AHAM's 2/3 rule: choose a smoke CADR of at least 2/3 of the room's area (8 ft ceiling). By that rule this model suits rooms up to about 147 sq ft.

Estimated yearly electricity cost

WhereResidential ratePer yearPer month
Louisiana12.72¢$8.14$0.68
U.S. average18.31¢$11.72$0.98
California33.61¢$21.51$1.79
Hawaii48.00¢$30.72$2.56

Estimate = 64 kWh/yr × rate. Rates: EIA Table 5.6.A, July 2026 (preliminary). Filter replacement cost is not included (data gap: not in ENERGY STAR data). Use your own rate and hours.

On battery during an outage (estimate): 64 kWh ÷ 5,840 active hours ≈ 11 W average, which runs slightly high because the annual figure includes standby. A 1,024 Wh portable power station at an assumed 85% inverter efficiency would run it about 79 h. Top fan speed can draw more. Try other stations in the runtime calculator on our power station site.

Similar CADR from other brands

ModelSmoke CADR (cfm)ENERGY STAR room size (sq ft)Energy use (kWh/yr)Est. electricity/yr*
Alen BreatheSmart 25i9715090$16.48
Honeywell HPA4100B10916995$17.39
Dreo DR-HTF022S90140102$18.68
Dreo DR-HAP006102158102$18.68
Dreo DR-HAP006S102158102$18.68

*Estimate: ENERGY STAR annual kWh × U.S. average residential rate 18.31¢/kWh (EIA, July 2026 (preliminary)). ENERGY STAR's annual figure assumes 16 hours/day of operation under the DOE test procedure.

Compare this model side by side with any other · All Blueair models

See Blueair air purifiers on the manufacturer's site (plain link, not an affiliate link)

We have not tested this product. Figures are as listed in ENERGY STAR data retrieved 2026-10-17.