Air Purifier CADR Check

Disclosure: Manufacturer links on this site are plain links, not affiliate links yet. If that changes we may earn a commission at no cost to you, and this notice will say so. We have not tested any product; all performance figures come from ENERGY STAR certification data, and cost and room-size figures are estimates. Learn more.

Midea KJ250G-Z42: CADR, room size and running cost

Smoke CADR 146 cfm · Room size 226 sq ft (ENERGY STAR) · 131 kWh/yr ≈ $23.99/yr electricity (estimate)

Certified specs

Smoke CADR146 cfm
Dust CADR148 cfm
Pollen CADR143 cfm
PM2.5 CADR147 cfm
ENERGY STAR effective room size226 sq ft (1.55 × smoke CADR, per 10 CFR 429.68)
Annual energy use131 kWh/yr
Integrated energy factor6.6 cfm/W
Smoke CADR per watt6.61 cfm/W
Ozone emissions (reported)1 ppb
TechnologyFan and Filter
Filter types listedHEPA-Type
Automatic modeNone
Connected (app/Wi-Fi)No
ENERGY STAR Most EfficientYes
MarketsUnited States, Canada
Date certified2021-12-16
ENERGY STAR partnerGD Midea Environment Appliances MFG Co., Ltd.
SourceENERGY STAR record 4439571 · Product Finder page

How many air changes per hour would it give?

Estimate: air changes per hour (ACH) = smoke CADR × 60 ÷ room volume, at the top fan speed used for the CADR test. Real-world ACH is usually lower (lower fan speeds, furniture, filter loading).

RoomACH, 8 ft ceilingACH, 9 ft ceilingAHAM sizing
100 sq ft10.99.7Meets AHAM 2/3 rule
150 sq ft7.36.5Meets AHAM 2/3 rule
200 sq ft5.54.9Meets AHAM 2/3 rule
300 sq ft3.63.2Below AHAM 2/3 rule
400 sq ft2.72.4Below AHAM 2/3 rule
500 sq ft2.21.9Below AHAM 2/3 rule
700 sq ft1.61.4Below AHAM 2/3 rule

AHAM's 2/3 rule: choose a smoke CADR of at least 2/3 of the room's area (8 ft ceiling). By that rule this model suits rooms up to about 219 sq ft.

Estimated yearly electricity cost

WhereResidential ratePer yearPer month
Louisiana12.72¢$16.66$1.39
U.S. average18.31¢$23.99$2.00
California33.61¢$44.03$3.67
Hawaii48.00¢$62.88$5.24

Estimate = 131 kWh/yr × rate. Rates: EIA Table 5.6.A, July 2026 (preliminary). Filter replacement cost is not included (data gap: not in ENERGY STAR data). Use your own rate and hours.

On battery during an outage (estimate): 131 kWh ÷ 5,840 active hours ≈ 22 W average, which runs slightly high because the annual figure includes standby. A 1,024 Wh portable power station at an assumed 85% inverter efficiency would run it about 39 h. Top fan speed can draw more. Try other stations in the runtime calculator on our power station site.

Similar CADR from other brands

ModelSmoke CADR (cfm)ENERGY STAR room size (sq ft)Energy use (kWh/yr)Est. electricity/yr*
Blueair 3132111100153237103.3$18.91
Blueair 3232111101147228108$19.77
Blueair 3232111100145225110$20.14
Blueair 4512311000161250110$20.14
Bosch Air 4000156242124$22.70
Cuckoo CAC-AB0610FI149231126$23.07
Dreame CVM10B137212128$23.44
Clorox TYPE AP32148229132$24.17

*Estimate: ENERGY STAR annual kWh × U.S. average residential rate 18.31¢/kWh (EIA, July 2026 (preliminary)). ENERGY STAR's annual figure assumes 16 hours/day of operation under the DOE test procedure.

Compare this model side by side with any other · All Midea models

See Midea air purifiers on the manufacturer's site (plain link, not an affiliate link)

We have not tested this product. Figures are as listed in ENERGY STAR data retrieved 2026-10-17.