Air Purifier CADR Check

Disclosure: Manufacturer links on this site are plain links, not affiliate links yet. If that changes we may earn a commission at no cost to you, and this notice will say so. We have not tested any product; all performance figures come from ENERGY STAR certification data, and cost and room-size figures are estimates. Learn more.

Blueair 3613111100: CADR, room size and running cost

Smoke CADR 443 cfm · Room size 687 sq ft (ENERGY STAR) · 259 kWh/yr ≈ $47.42/yr electricity (estimate)

Data gap: ENERGY STAR lists this model by its model number only. We do not map it to a marketing name unless ENERGY STAR itself does, so check the model number on the box or the manufacturer's page.

Certified specs

Smoke CADR443 cfm
Dust CADR457 cfm
Pollen CADR450 cfm
PM2.5 CADR450 cfm
ENERGY STAR effective room size687 sq ft (1.55 × smoke CADR, per 10 CFR 429.68)
Annual energy use259 kWh/yr
Integrated energy factor10.2 cfm/W
Smoke CADR per watt10.14 cfm/W
Ozone emissions (reported)2 ppb
TechnologyFan and Filter
Filter types listedHEPA-Type
Automatic modeNone
Connected (app/Wi-Fi)Yes (Wi-Fi)
ENERGY STAR Most EfficientYes
MarketsUnited States, Canada
Date certified2023-03-22
ENERGY STAR partnerBlueair Inc.
SourceENERGY STAR record 4510390 · Product Finder page

How many air changes per hour would it give?

Estimate: air changes per hour (ACH) = smoke CADR × 60 ÷ room volume, at the top fan speed used for the CADR test. Real-world ACH is usually lower (lower fan speeds, furniture, filter loading).

RoomACH, 8 ft ceilingACH, 9 ft ceilingAHAM sizing
100 sq ft33.229.5Meets AHAM 2/3 rule
150 sq ft22.119.7Meets AHAM 2/3 rule
200 sq ft16.614.8Meets AHAM 2/3 rule
300 sq ft11.19.8Meets AHAM 2/3 rule
400 sq ft8.37.4Meets AHAM 2/3 rule
500 sq ft6.65.9Meets AHAM 2/3 rule
700 sq ft4.74.2Below AHAM 2/3 rule

AHAM's 2/3 rule: choose a smoke CADR of at least 2/3 of the room's area (8 ft ceiling). By that rule this model suits rooms up to about 664 sq ft.

Estimated yearly electricity cost

WhereResidential ratePer yearPer month
Louisiana12.72¢$32.94$2.75
U.S. average18.31¢$47.42$3.95
California33.61¢$87.05$7.25
Hawaii48.00¢$124.32$10.36

Estimate = 259 kWh/yr × rate. Rates: EIA Table 5.6.A, July 2026 (preliminary). Filter replacement cost is not included (data gap: not in ENERGY STAR data). Use your own rate and hours.

On battery during an outage (estimate): 259 kWh ÷ 5,840 active hours ≈ 44 W average, which runs slightly high because the annual figure includes standby. A 1,024 Wh portable power station at an assumed 85% inverter efficiency would run it about 20 h. Top fan speed can draw more. Try other stations in the runtime calculator on our power station site.

Similar CADR from other brands

ModelSmoke CADR (cfm)ENERGY STAR room size (sq ft)Energy use (kWh/yr)Est. electricity/yr*
Coway AP-3018B413640235$43.03
Levoit LAP-C601S-WUS391606387$70.86
Cuckoo CAC-AH2810FNW455705388$71.04
Coway Airmega 450443687389$71.23
Levoit LAP-C601S-WUSR394611389$71.23
Coway Airmega 450S443687399$73.06
Winix Tower XQ461715486$88.99

*Estimate: ENERGY STAR annual kWh × U.S. average residential rate 18.31¢/kWh (EIA, July 2026 (preliminary)). ENERGY STAR's annual figure assumes 16 hours/day of operation under the DOE test procedure.

Compare this model side by side with any other · All Blueair models

See Blueair air purifiers on the manufacturer's site (plain link, not an affiliate link)

We have not tested this product. Figures are as listed in ENERGY STAR data retrieved 2026-10-17.